12/14 (top angle 5°42'30") BIOLOX approved
Surface coated with bio-active materials as pure Titanium and Hydroxyapatite to enhance primary stability and promote biological integration.
Vertical and horizontal grooves provides rotational and torsional stability.
Sandblasted surface
12/14 (top angle 5°42'30") BIOLOX approved
Polished or Matt (sandblasted) surface
Smoothed profile
Sinking level marks
Distal centralizer
Titanium | HaX-Pore | X-Pore | HA | |||||
---|---|---|---|---|---|---|---|---|
Size | L1(mm) | L(mm) | Offset(mm) | L2(mm) | Reference | Reference | Reference | Reference |
1 | 130.5 | 110 | 40.0 | 41.0 | 11501 | 11901 | 11801* | 11601* |
2 | 140.5 | 120 | 40.5 | 41.0 | 11502 | 11902 | 11802* | 11602* |
3 | 145.5 | 125 | 41.0 | 42.0 | 11503 | 11903 | 11803* | 11603* |
4 | 150.5 | 130 | 42.0 | 43.0 | 11504 | 11904 | 11804* | 11604* |
5 | 155.5 | 135 | 43.3 | 44.0 | 11505 | 11905 | 11805* | 11605* |
6 | 160.5 | 140 | 43.5 | 44.5 | 11506 | 11906 | 11806* | 11606* |
7 | 165.5 | 145 | 44.5 | 45.0 | 11507 | 11907 | 11807* | 11607* |
8 | 170.5 | 150 | 45.0 | 45.0 | 11508 | 11908 | 11808* | 11608* |
9 | 175.4 | 154 | 45.0 | 45.2 | 11529 | 11929 | 11829* | 11609* |
10 | 180.4 | 158 | 45.5 | 45.2 | 11530 | 11930 | 11830* | 11610* |
11 | 185.4 | 162 | 45.5 | 45.8 | 11531 | 11931 | 11831* | 11611* |
12 | 190.4 | 166 | 46.0 | 46.5 | 11532 | 11932 | 11832* | 11612* |
Titanium | HaX-Pore | X-Pore | HA | |||
---|---|---|---|---|---|---|
Size | Offset(mm) | L2(mm) | Reference | Reference | Reference | Reference |
1 | 46.0 | 45.8 | 11511 | 11911 | 11841* | 11621* |
2 | 46.5 | 46.0 | 11512 | 11912 | 11842* | 11622* |
3 | 48.0 | 47.5 | 11513 | 11913 | 11843* | 11623* |
4 | 49.0 | 48.5 | 11514 | 11914 | 11844* | 11624* |
5 | 50.0 | 49.5 | 11515 | 11915 | 11845* | 11625* |
6 | 51.0 | 50.5 | 11516 | 11916 | 11516* | 11626* |
7 | 52.0 | 51.0 | 11517 | 11917 | 11847* | 11627* |
8 | 52.5 | 51.0 | 11518 | 11918 | 11848* | 11628* |
9 | 52.5 | 51.5 | 11539 | 11937 | 11849* | 11629* |
10 | 53.0 | 52.0 | 11540 | 11938 | 11850* | 11630* |
11 | 53.0 | 52.0 | 11541 | 11939 | 11851* | 11631* |
12 | 53.5 | 52.5 | 11542 | 11940 | 11852* | 11632* |
Polished | Matt | |||||
---|---|---|---|---|---|---|
Size | L1(mm) | L(mm) | Offset(mm) | L2(mm) | Reference | Reference |
1 | 117 | 97 | 40.0 | 39.0 | 11701 | 11771* |
2 | 120 | 100 | 40.5 | 39.0 | 11702 | 11772* |
3 | 130 | 110 | 41.0 | 39.0 | 11703 | 11773* |
4 | 135 | 115 | 42.0 | 40.0 | 11704 | 11774* |
5 | 140 | 120 | 43.3 | 41.0 | 11705 | 11775* |
6 | 145 | 125 | 43.5 | 42.0 | 11706 | 11776* |
7 | 150 | 130 | 44.5 | 42.7 | 11707 | 11777* |
8 | 155 | 135 | 45.0 | 43.3 | 11708 | 11778* |
9 | 160 | 140 | 45.0 | 43.3 | 11729 | 11779* |
10 | 165 | 145 | 45.5 | 43.3 | 11730 | 11780* |
11 | 170 | 150 | 45.5 | 44.0 | 11731 | 11781* |
12 | 175 | 155 | 46.0 | 44.5 | 11732 | 11782* |
Polished | Matt | |||
---|---|---|---|---|
Size | Offset(mm) | L2(mm) | Reference | Reference |
1 | 46.0 | 43.0 | 11711 | 11786* |
2 | 46.5 | 43.0 | 11712 | 11787* |
3 | 48.0 | 43.5 | 11713 | 11788* |
4 | 49.0 | 45.5 | 11714 | 11789* |
5 | 50.0 | 46.5 | 11715 | 11790* |
6 | 51.0 | 47.0 | 11716 | 11791* |
7 | 52.0 | 47.8 | 11717 | 11792* |
8 | 52.5 | 48.4 | 11718 | 11793* |
9 | 52.5 | 48.4 | 11739 | 11794* |
10 | 53.0 | 48.4 | 11740 | 11795* |
11 | 53.0 | 49.0 | 11741 | 11796 |
12 | 53.5 | 49.5 | 11742 | 11797 |
EXACTA stems are intended for use in total or partial Hip Replacement procedures, combined with a femoral ball head (or a bi- articular head) and an acetabular cup. Indicated for primary hip arthroplasties in cases of serious joint degeneration, mainly due to arthrosis and post- traumatic degenerative factors. Device fixation is obtained by means of primary cementless press-fit stabilization or by using bone cement, depending on the version utilized.
Cementless stems: Titanium Aluminium Niobium forged alloy (Ti6Al7Nb)
Cemented stem: ISO5832/11 PM734 higly nitrogenized Stainless Steel
EXACTA Titanium: microstructured sandblasted surface roughness 4-6µm
EXACTA HaX-Pore: double coating 300µm pure Titanium+50µm Hydroxyapatite Ca10(OH)2(PO4)6 plasma sprayed
EXACTA X-Pore: coating 300µm pure Titanium plasma sprayed
EXACTA HA: coating 80µm Hydroxyapatite Ca10(OH)2(PO4)6 plasma sprayed
EXACTA Plus: mirror polished or matt (sandblasted, on request) finishing surface
Method: Irradiation (nominal dose 25 kGy), in vacuum.
Validity: 5 years.
CLASS III as reported in Directive 2005/50/CE (and related D.lgs 26 april 2007 n.65) concerning re-classification of Hip, Knee and Shoulder joint prostheses which modifies classification criteria of Annex IX of Directive 93/42/CEE and next integrations and amendements.