Pressfit-Cups

JUMP System - Accepts All Types of Inserts

15 Implant sizes

Hemispherical geometry with polar deflection. ULTRAFIT® finishing along the equatorial rim to maximize press-fit insertion.

Surface coated with bio-active materials as pure Titanium and Hydroxyapatite to enhance primary stability and promote biological integration.

BIOLOX® ceramic inserts locks into the cup thanks to the taper connection. UHMWPE and VITAL-XE inserts, more than the taper connection, locks into the cup thanks to a patented locking system which ensures retention and rotational stability.

Screw holes are sealed by apposite plugs that can be removed in case additional screw fixation is required.

Dual Mobility option

JUMP® SYSTEM Dual Mobility insert represents an effective solution for those cases where a high possibility of dislocation can be expected (patients with poor muscle tone or neuromotor control). Metal insert fitting into the cup and accepts ACORN Dual Mobility UHMWPE or VITAL-XE articular inserts.

JUMP System PE - Accepts only UHMWPE and VITAL-XE inserts

4 Implant Sizes

The JUMP System PE option has been realized to allow use of large heads even in small size cups.

Cup size Insert Socket
Ø 48-50mm Ø 36mm
Ø 52-54mm Ø 36-40mm

It is available in 4 sizes (48-50-52-54) with metalback of reduced thickness and only works with Polyethylene inserts (UHMWPE and VITAL-XE). Screw holes are open and cannot be sealed.

* References with asterisk are available ON REQUEST
JUMP® System Cementless Press-Fit Cups
Standard X-Pore HA HaX-Pore
Size Reference Reference Reference Reference
42 35142* 35242* 35442* 35342*
44 35145 35244 35444 35345
46 35147 35246 35446 35347
48 35149 35248 35448 35349
50 35150 35250 35450 35350
52 35153 35252 35452 35353
54 35155 35254 35454 35355
56 35156 35256 35456 35356
58 35158 35258 35458 35358
60 35160 35260 35460 35360
62 35162 35262 35462 35362
64 35164 35264 35464 35364
66 35166* 35266* 35466* 35366*
68 35168* 35268* 35468* 35368*
70 35170* 35270* 35470* 35370*
JUMP® System Cementless Press-Fit Cups
Standard X-Pore HA HaX-Pore
Size Reference Reference Reference Reference
48 35791 35991 35491 35881
50 35792 35992 35492 35883
52 35793 35993 35493 35882
54 35794 35994 35494 35884
JUMP® System Cementless Press-Fit Cups
Standard X-Pore HA HaX-Pore
Size Reference Reference Reference Reference
48 35781* 35981* 35481* 35681*
50 35782* 35982* 35482* 35682*
52 35783* 35983* 35483* 35683*
54 35784* 35984* 35484* 35684*
JUMP SYSTEM Dual Mobility Option - Class III
BIOLOY PM734 BIOLOY CrCo
Cup Size Colour Code Reference Reference
44-46 BLACK 36215 36205
48-50 YELLOW 36211 36201
52-54 GREY 36212 36202
56-60 BLUE 36213 36203
62+ RED 36214 36204
UHMWPE VITAL-E ®
Ø inner Ø outer Colour Code Reference Reference
22mm 36mm BLACK 38844 38844E
28mm 38mm YELLOW 38846 38846E
28mm 40mm GREY 38848 38848E
28mm 44mm BLUE 38852 38852E
28mm 46mm RED 38854 38854E
Accessories Class IIb
Polor Plug
Reference
Fixation Screws Ø 6,5 mm
Length Reference
20mm 36720
25mm 36725
30mm 36730
35mm 36735
40mm 36740
45mm 36745
50mm 36750
60mm 36760

Order Information

* References with asterisk are available ON REQUEST
JUMP SYSTEM Articular Inserts - Class III
UHMWPE VITAL-XE ® BIOLOX® Delta
20° 20°
Socket Reference Reference Reference Reference Reference
22mm 36303* 36304*
28mm 36301 36302 36301XE 36302XE 36007*
36305 36306 36305XE 36306XE
36311 36312 36311XE 36312XE
36321 36323 36321XE 36323XE
36307 36308 36307XE 36308XE
36309 36310 36309XE 36310XE
32mm 36313 36314 36313XE 36314XE 36011
36319 36320 36319XE 36320XE 36016
36340 36342 36340XE 36342XE 36015
36315 36316 36315XE 36316XE 36017
36317 36318 36317XE 36318XE 36018
36mm 36343 36345 36343XE 36345XE 36022
36325 36326 36325XE 36326XE 36025
36327 36328 36327XE 36328XE 36026
40 mm 36346 36347 36346XE 36347XE 36041
36348 36349 36348XE 36349XE 36042

Information

INTENDED PURPOSE:

JUMP® System is an acetabular component for cementless applications to be used in Total Hip Replacement procedures in combination with an articular liner, a femoral ball-head and a femoral stem. Indicated in primary and revision hip arthroplasties, all cases of coxarthrosis where the bony tissue is suitable enough to guarantee a correct and stable primary mechanical press-fit fixation.

Anchorage of the device to the bone is achieved by press-fit insertion. Whenever necessary, fixation can be improved by using cancellous bone screws inserted into the dedicated holes.

STERILIZATION:

Method: Ethylene Oxyde (ETO) or accelerated electron beam irradiation (ß rays - nominal dose 25 kGy), in vacuum.

Validity: 5 years.

CLASSIFICATION:

CLASS III or llb as reported in Directive 2005/50/CE (and related D.lgs 26 april 2007 n.65) concerning re-classification of Hip, Knee and Shoulder joint prostheses which modifies classification criteria of Annex IX of Directive 93/42/CEE and next integrations and amendements.

MATERIALS:
CUPS, SCREWS, PLUGS:

Titanium Aluminium Vanadium Ti6Al4V Alloy - ISO5832/3.

INSERTS:

UHMWPE: Ultra High Molecular Weight Polyethylene without Calcium Stearate - ISO5834/1/2.

VITAL-XE: cross-linked UHMWPE added with Vitamin E - ISO5834/1/2.

CERAMIC: BIOLOX® Delta mix of Alumina and Zirconia Oxide (Al O + ZrO ) - ISO6474

Metal Dual Mobility:

- PM734 higly nitrogenized Stainless Steel forged alloy ISO5832/9

- CrCoMo forged alloy ISO5832/12

SURFACE FINISHING:

HaX-Pore: 500µm pure Titanium + 40µm Hydroxyapatite Ca10(OH)2(PO4)6 applied with plasma spray technique.

X-Pore: 500µm pure Titanium applied with plasma spray technique.

HA: 80µm Hydroxyapatite Ca10(OH)2(PO4)6 applied with plasma spray technique.

Standard: microstructured sandblasted surface (ra ± 4-6µm).

BIOLOY®: TiNbN coating (Dual Mobility inserts).