Traser

TRASER Random Trabecular Laser Technology

JUMP® SYSTEM TRASER® cup is obtained through Selective Laser Melting additive manufacturing process, which allows to obtain solid objects from 3D-CAD digital models by adding the raw material (Ti6Al4V powder) layer over layer up to completion of the object.

The randomized size and geometrical shape of the Titanium trabecular surface provides optimal structure for bone ingrowth and secondary biological fixation of the implant.

JUMP® SYSTEM TRASER® - Accepts all types of inserts

14 Implant sizes

Hemispherical geometry with polar deflection. TRASER® random trabecular structure to ensure strong grip for primary fixation by press-fit insertion and favouring bone ingrowth.

BIOLOX® ceramic inserts locks into the cup thanks to the taper connection. UHMWPE and VITAL-XE inserts, more than the taper connection, locks into the cup thanks to a patented locking system which ensures retention and rotational stability.

Screw holes are sealed by apposite plugs that can be removed in case additional screw fixation is required.

Dual Mobility option

JUMP® SYSTEM Dual Mobility insert represents an effective solution for those cases where a high possibility of dislocation can be expected (patients with poor muscle tone or neuromotor control).

Metal insert fitting into the cup and accepts ACORN Dual Mobility UHMWPE or VITAL-E articular inserts.

JUMP® SYSTEM TRASER® - Accepts only PE and VITAL-XE inserts

17 Implant Sizes

TRASER® Revision version has a multi-hole configuration to allow fixation screws placement in a wider area and a range of sizes making it suitable for revision cases.

JUMP® System TRASER® Cementless Cups
TRASER®
Size Reference
44 39344
46 39346
48 39348
50 39350
52 39352
54 39354
56 39356
58 39358
60 39360
62 39362
64 39364
66 39366
68 39368
70 39370
JUMP® System TRASER® Cementless Cups
TRASER® REVISION
Size Reference
48 39448
50 39350
52 39452
54 39454
56 39456
58 39458
60 39460
62 39462
64 39464
66 39466
68 39468
70 39470
72 39472
74 39474
76 39476
78 39478
80 39480
JUMP SYSTEM Dual Mobility Option - Class III
BIOLOY PM734 BIOLOY CrCo
Cup Size Colour Code Reference Reference
44-46 BLACK 36215 36205
48-50 YELLOW 36211 36201
52-54 GREY 36212 36202
56-60 BLUE 36213 36203
62+ RED 36214 36204
UHMWPE VITAL-E ®
Ø inner Ø outer Colour Code Reference Reference
22mm 36mm BLACK 38844 38844E
28mm 38mm YELLOW 38846 38846E
40mm GREY 38848 38848E
44mm BLUE 38852 38852E
46mm RED 38854 38854E
Accessories Class IIb
Sealing Plugs
Reference
35103
Fixation Screws Ø 6,5 mm
Length Reference
20mm 36720
25mm 36725
30mm 36730
35mm 36735
40mm 36740
45mm 36745
50mm 36750
60mm 36760
JUMP SYSTEM Articular Inserts
UHMWPE VITAL-XE ® BIOLOX® Delta
10° 20° 10° 20°
Socket Reference Reference Reference Reference Reference Reference Reference
28mm 36301 36363 36302 36301XE 36363XE 36302XE
36305 36364 36306 36305XE 36364XE 36306XE
36311 36365 36312 36311XE 36365XE 36312XE
36307 36366 36308 36307XE 36366XE 36308XE
36309 36367 36310 36309XE 36367XE 36310XE
32mm 36011
36313 36368 36314 36313XE 36368XE 36314XE 36016
36319 36369 36320 36319XE 36369XE 36320XE 36015
36315 36370 36316 36315XE 36370XE 36316XE 36017
36317 36371 36318 36317XE 36371XE 36318XE 36018
36mm 36380XE 36382XE 36381XE 36022
36325 36329 36326 6325XE 36329XE 36326XE 36025
36327 36330 36328 36327XE 36330XE 36328XE 36026
40 mm 36346 36347 36346XE 36347XE 36041
36348 36349 36348XE 36349XE 36042
Information:
INTENDED PURPOSE:

JUMP® System TRASER® is an acetabular component for cementless applications to be used in Total Hip Replacement procedures in combination with an articular liner, a femoral ball-head and a femoral stem. Indicated in primary and revision hip arthroplasties, all cases of coxarthrosis where the bony tissue is suitable enough to guarantee a correct and stable primary mechanical press-fit fixation.

Anchorage of the device to the bone is achieved by press-fit insertion. Whenever necessary, fixation can be improved by using cancellous bone screws inserted into the dedicated holes.

STERILIZATION:

Method: Ethylene Oxyde (ETO) or accelerated electron beam irradiation (ß rays - nominal dose 25 kGy), in vacuum.

Validity: 5 years.

CLASSIFICATION:

Class III or llb as reported in Directive 2005/50/CE (and related D.lgs 26 april 2007 n.65) concerning re-classification of Hip, Knee and Shoulder joint prostheses which modifies classification criteria of Annex IX of Directive 93/42/CEE and next integrations and amendments

Materials:
CUPS, SCREWS, PLUGS:

Titanium Aluminium Vanadium Ti6Al4V Alloy - ISO5832/3.

INSERTS:

UHMWPE: Ultra High Molecular Weight Polyethylene without Calcium Stearate - ISO5834/1/2.

VITAL-XE: cross-linked UHMWPE added with Vitamin E - ISO5834/1/2.

CERAMIC: BIOLOX® Delta mix of Alumina and Zirconia Oxide (Al2O3 + ZrO2) - ISO6474.

Metal Dual Mobility:

- PM734 higly nitrogenized Stainless Steel forged alloy ISO5832/9

- CrCoMo forged alloy ISO5832/12

SURFACE FINISHING:

TRASER®: Randomized trabecular metal structure with average pores SIZE of 650µm.

BIOLOY®: TiNbN coating (Dual Mobility inserts)